Discussion in building started by dave mitch 26 may 2020.

Chimney back gutter flashing.

The complication being as i hope you can see from the picture is that the end of the back gutter lead meets the edge of the wall is only about 4 from where the corrugated sheets will end i will be adding guttering i can t see how step flashing will help stop water running off the sole plate running straight under the sheeting. Chimney flashing with box gutter. Chimney flashing and cap. It is installed to ensure that the lead flashing wraps around the tilting fillet and is overlapped by the roofing underlay.

I am replacing the corrugated sheeting and have also had a proper back gutter made to replace the cobbled piece of lead that was letting in water. The back gutter is fitted to carry water from behind the chimney. Patination oil 1ltr patination oil 1ltr quantity. This forms a secret gutter behind the chimney extending at least 125 mm up the chimney framing.

At the rear of the chimney a butyl epdm or lead gutter lining is carried over an anti ponding board. Technical details flashing materials. They can be folded in a wide selection of gauges ranging from 0. These back gutters are all made to order to ensure you get the best product for your property.

L shaped flashing is a versatile general use flashing used where a uniform or strengthened finish is needed on a 90 surface. It is then dressed down over the lower flashing see figures 1 and 2. Chimney back gutter flashing. All these items are made from code 4 sheet lead to bs en 12588.

Stratco flashings are available in galvanised unpainted zinc al pre painted colour steel aluminium stainless steel and copper. 26 may 2020 messages. A simple solution may be to take a couple of rows of tiles of behind the chimney and were the felt runs under your back gutter slice the felt along the wood thats supporting the lead if that means taking out a few of the thin counter batons so you can slice the felt do it then you can gently lift the felt back and insert a small piece of baton to hold the felt up which should be enough to. Lead back gutter quantity.

We supply lead back gutters to suit any chimney flashing and orientation.

Chimney Repair 3 Most Common Reasons Chimneys Leak Roof Roof Repair Home Construction

Chimney Repair 3 Most Common Reasons Chimneys Leak Roof Roof Repair Home Construction

Ibstock Chimney Jpg 882 833

Ibstock Chimney Jpg 882 833

General Chimney Repair Covers All Sorts Of Construction And Reconstruction Done On Chimneys As Well As Servi Chimney Cap Brick Chimney Chimney Cleaning

General Chimney Repair Covers All Sorts Of Construction And Reconstruction Done On Chimneys As Well As Servi Chimney Cap Brick Chimney Chimney Cleaning

Pin On Projects To Try

Pin On Projects To Try

Source : pinterest.com