It enters the air handling unit cools the air in cooling coil absorbs the heat and returns back to the plant room to get.
Chiller plant chilled water system diagram.
Chilled water schematic and condenser water schematic how to read and understand the engineering drawings with real world examples illustrations animations and video tutorial.
However the purpose of a chiller remains the same.
How does a chiller work.
This cool fluid removes heat from the process and the warm fluid returns to the chiller.
The process fluid absorbs heat from what is being cooled and then goes through the chiller where the heat is removed from the fluid and transferred to the.
Chilled water plant system diagram exercise this is an updated version of an exercise i originally published on the blog back in september of 2013.
To remove heat from water.
This means not only the delivered capacity of the chillers is reduced but also.
To put it simply industrial chillers cool process fluids.
In most process cooling applications a pumping system circulates cool water or a water glycol solution from the chiller to the process.
A chilled water system is a cooling system in which chilled water is circulated throughout.
The plant operators turn on extra chillers and associated pumps to provide the needed capacity.
I posted it to provide an on line version of an exercise i had done in class which was the first time i had tried using a sketchup model as a teaching aid.
Chilled water systems provide cooling to a building by using chilled water to absorb heat from the building s spaces.
The evaporator of the chiller is where the chilled water is generated.
The chilled water leaves the evaporator at around 6 c 42 8 f and is pushed around the building by the chilled water pump.
Chilled water system basics.
System flow below chiller min flow 250 gpm variable primary flow at 25 system load two way valves control capacity by varying flow of water in coils per chiller system load 50 tons 176kw 50tons 176 kw primary bypass flow 250 gpm 95 l s 150 gpm 9 5 l s delta t 12 of 6 7 oc 100 gpm 44 ºf 6 3 l s 6 7 ºc 56 ºf 13 3 ºc 150.
At the heart of the water chilled system a chiller removes heat from water by means of a refrigeration cycle.
If the water flows along tube side and the refrigerant along the shell side it is called as the flooded chiller.
How a chiller works.
The chilled water flows up the height of the building to each floor in pipes known as risers.
Process fluids typically water or a water glycol mix are used to cool machinery equipment food etc.